19 November, 2026

One Clip for a Broad Jet: TEER for Severe Functional MR After CABG

Mitral Live · Case 2 of 4 · Functional MR TEER

An 80-year-old man with previous bypass surgery and a severely weakened heart was admitted with pulmonary oedema. A new, severe leak in his mitral valve was driving it. One clip, delivered through a vein, sealed the broad jet.

5 min read
80 yearsPrevious CABG
Severe LV impairmentAdmitted with pulmonary oedema
1 XTW clipSingle-clip TEER
Day 2Discharged home
1

The patient: a weak heart and a new leak

An 80-year-old man who had previously undergone coronary bypass surgery (CABG) had severe impairment of his left ventricle. He was admitted with pulmonary oedema, and imaging showed new-onset severe functional mitral regurgitation with a broad jet.

Age 80Previous CABGSevere LV impairmentSevere functional MRBroad jet
2

Functional MR: a normal valve in a failing heart

In functional (secondary) MR, the mitral leaflets themselves are normal. The problem is the ventricle: as it weakens and enlarges, it pulls the leaflets apart so they no longer meet. Blood leaks backwards with every beat, adding to the strain on an already failing heart and pushing fluid into the lungs.

Baseline TEE
Before. Severe functional MR with a broad jet on colour Doppler.
TEE + 3D
Baseline assessment of the jet with colour and 3D imaging.
3

The procedure: TEER with one XTW clip

For an 80-year-old after previous heart surgery, with a weak ventricle, reopening the chest carries high risk. Instead, we performed transcatheter edge-to-edge repair (TEER): a clip is delivered through a vein in the leg, across the septum, and used to grasp the two leaflets together where the leak is largest. Given the broad jet, we chose the wider XTW clip.

Fluoroscopy
Clip delivery. The XTW clip positioned under imaging guidance.
TEE
TEE guidance during clip positioning.
3D en-face
Surgeon’s view. 3D en-face view of the clip on the mitral valve.
TEE
TEE view after clip deployment.
4

The result

One XTW clip achieved a good procedural and clinical end point. He was discharged on Day 2.

Final TEE
After one XTW. Final colour Doppler.
5

What this case teaches

01Treat the leak, help the heart

Reducing functional MR takes load off a failing ventricle.

02Match the clip to the jet

A wider clip can address a broad jet with a single device.

03No redo surgery

TEER avoided reopening the chest in an 80-year-old after CABG.

Part of Mitral Live: four transcatheter mitral therapies performed live between 8 am and 1 pm, with all four patients discharged on Day 2. Read the other cases: Case 1: PTMC for rheumatic mitral stenosis · Case 3: Two-clip TEER for a flail P2 segment · Case 4: TMVR valve-in-valve in a failed surgical valve.

With thanks to our Mitral Live expert panel, Dr Pahlajani, Dr Praveen Chandra, Dr R Anantharaman, Dr Vijay Iyer and Dr Rahul Mehrotra, for their inputs and discussion.

Leaking mitral valve and heart failure?

Our structural heart team offers TEER for patients with functional MR who are high risk for conventional surgery.

Request a consultation

This case is shared for medical education. Images and clips are de-identified procedural recordings. Individual outcomes vary, and treatment decisions should be made with your cardiologist.

Share