19 November, 2026

A Third Mitral Valve Without a Third Operation: TMVR Valve-in-Valve in a Failed Magna Ease

Mitral Live · Case 4 of 4 · TMVR Valve-in-Valve

A 78-year-old woman had already had two open-heart mitral valve operations. When her surgical valve wore out and narrowed, we gave her a third valve, implanted through a catheter inside the old one, without a third operation.

5 min read
2 prior surgeriesMVR in 2006, redo in 2016
Severe MSDegenerated 25 mm Magna Ease
23 mm Sapien XTValve-in-valve, +4 ml volume
No MSFinal result
1

The patient: a worn-out surgical valve

A 78-year-old woman had undergone two surgical mitral valve replacements: the first in 2006 and a redo in 2016. She now presented with severe mitral stenosis, because her latest valve, a 25 mm Magna Ease bioprosthesis, had degenerated, with calcified leaflets.

Age 78Two previous MVRs25 mm Magna EaseCalcific degenerationSevere MS
TEETEE assessment of the degenerated surgical valve.
TEE assessment of the degenerated surgical valve.
TEE
Colour Doppler across the stenotic surgical valve.
2

Why not a third operation, or a valve fracture?

A third open-heart operation carries high risk. Some surgical valves can be cracked open with a high-pressure balloon (bioprosthetic valve fracture, BVF) to make room for a larger new valve, but BVF is usually not successful in a Magna Ease.

The other key risk in mitral valve-in-valve is blocking the outflow of the left ventricle (LVOT obstruction). CT showed no risk of LVOT obstruction, so she was a good candidate for transcatheter mitral valve-in-valve (TMVR ViV).

3

The procedure: a new valve inside the old one

Through a vein and across the septum, we deployed a 23 mm Sapien XT inside the surgical valve, with 4 ml of extra volume in the delivery balloon to expand it fully against the old valve frame.

TEE
TEE guidance during valve positioning.
Fluoroscopy
Valve-in-valve. The Sapien XT deployed inside the surgical valve.
FluoroscopyFinal position. The new valve seated within the surgical valve ring.
Final position. The new valve seated within the surgical valve ring.
4

The result: no mitral stenosis

The new valve achieved no MS, without a third open-heart operation. She was discharged on Day 2.

TOE after TMVR
After TMVR. Colour Doppler of the new valve.
3D en-face
3D en-face view of the new valve inside the surgical ring.
5

What this case teaches

01Surgical valves wear out

Tissue valves can degenerate years later, and a redo operation gets riskier each time.

02Know the valve

The surgical valve model matters: in a Magna Ease, BVF is usually not successful, which shapes the plan.

03CT planning is essential

Ruling out LVOT obstruction on CT makes mitral valve-in-valve a safe option.

Part of Mitral Live: four transcatheter mitral therapies performed live between 8 am and 1 pm, with all four patients discharged on Day 2. Read the other cases: Case 1: PTMC for rheumatic mitral stenosis · Case 2: TEER for functional MR after CABG · Case 3: Two-clip TEER for a flail P2 segment.

With thanks to our Mitral Live expert panel, Dr Pahlajani, Dr Praveen Chandra, Dr R Anantharaman, Dr Vijay Iyer and Dr Rahul Mehrotra, for their inputs and discussion.

Failing surgical valve? There may be an alternative to redo surgery

Our structural heart team performs transcatheter valve-in-valve procedures for patients with degenerated surgical valves.

Request a consultation

This case is shared for medical education. Images and clips are de-identified procedural recordings. Individual outcomes vary, and treatment decisions should be made with your cardiologist.

Share